Weight-based doses rarely match vial sizes, so the leftover is discarded and still billed; closed-system vial sharing and rounding doses to the nearest vial within 10% eliminate most of that waste.
Medicare pays for discarded drug under the JW modifier and, since 2023, requires refunds from manufacturers for waste above 10% under the Infrastructure Investment and Jobs Act. Pharmacies can avoid the waste in the first place: closed-system transfer devices extend the in-use stability of single-dose vials so one vial serves several patients, and dose banding (rounding to the nearest vial size within a defined tolerance) is standard in the NHS. Both are cheap and can be implemented by a hospital pharmacy in months.